-40%
AVO/Multi-Amp/Biddle/Megger EPS-1000 Electronic Phase Shifter Relay Test Set
$ 4485.41
- Description
- Size Guide
Description
AVO/Multi-Amp/Biddle EPS-1000 Electronic Phase Shifter Test SetComes with what you see in the pictures. If you don't see it, you probably won't get it.
Specifications are from AVO/Multi-Amp and may vary slightly due to upgrades, options, or revisions this unit may or may not have.
This unit ships fully tested and guaranteed to work for 30-days, parts and labor, excluding freight. The unit is either new or like-new.
The Unit's Serial Number Tag Reads:
Serial Number:
146859-002/1
Firmware Version:
2.0
Modules Installed:
Qty. 3: Power Amplifier, Part Number: 15220-1
Qty. 1: CPU, Part Number: 14759
Qty. 1: LCD, Part Number: 14785
Qty. 1: Sine, Part Number: 14609
Qty. 1: Sync Detect, Part Number: 14689
Highlights:
Single-phase input
Selectable voltage output
Graphic display screen
Automatic fault testing
Stores 60 test files
Field portable
Features & Benefits:
Graphically displays voltage and phase angles to visually monitor the values for testing protective relays.
Single-phase; three-phase open delta; three-phase T-connect; three-phase wye; and three-phase delta output fo both voltages and phase angels for testing virtually all protective relays.
Output voltages and phase angles are indepently or simultaneously selectable and fully adjustable in performing three-phase or phase-to-phase tests.
Voltage phase angles are adjustable from 0 to 360° to provide multiple fault testing parameters and calibration settings.
Programmable delayed switching from Normal to Fault to Post-Fault conditions automatically simulates a dynamic test.
Saves up to 60 individual test files for identifying each protective relay test using 19 ASCII cahracters.
Option screen allows operator full, customized use of Model EPS-1000 for testing complex protective relays and offers easy setup of individual test parameters.
Compatible with five languages: English, Spanish, German, Portuguese and French.
Recessed front panel eliminates the need for a front panel cover.
Soft-side carrying case provides for easy carrying and superior protection of the test set.
Modular design permits replacement of individual modules and NIST calibration.
Applications:
Model EPS-1000 is a compatible test set for testing three-phase protective relays with Multi-Amp models SR-90, SR-76, and SR-51 test sets. When used with a Multi-Amp relay test set, Model EPS-1000 allows testing of a variety of complex relays. The protective relays and their respective IEEE devices numbers are (Relay types tested with EPS-1000 and SR-90):
Impedance - IEEE 21
Synchronizing - IEEE 25
Directional Power - IEEE 32
Loss-Of-Excitation or Field - IEEE 40
Negative Sequence Undervoltage - IEEE 47
Directional Overcurrent - IEEE 67
Description:
The EPS-1000 is a portable, self-contained, third generation test set providing a single-phase, phase-to-phase, or three-phase voltage source for testing complex protective relays. The EPS1000 graphically displays all voltage and phase angle settings, providing the operator graphic information, to know, the voltage amplitudes and phase angles applied to the relay. The graphic screen displays these voltage and phase angle settings with a full range of capabilities for modifying specific testing applications.
The EPS-1000 is a compatible test set for testing three phase protective relays with any of the following AVO Multi-Amp test equipment; SR-90, -76, or -51. The EPS-1000 utilizes other OEM test equipment, provided the input synchronization to the EPS1000 does not exceeded 30 VRMS or 5 A.
The EPS-1000 also has the capabilities to produce a single-phase, open-delta, T-connect, delta, or wye voltage source. These configurations display graphically on the EPS-1000 front panel display. Voltage amplitudes and phase angles are controlled using a numerical keypad or a rotary knob. Additional functions include; rotating one-phase, two-phases, or three-phases at a time.
Specifications:
Input Voltage:
95 to 265 VAC
Reference Input:
Current:
0 to 5 A
Voltage:
0 to 30 V
Internal Reference:
Phase lock to crystal oscillator
External Reference Indicator:
Indicates phase lock to external source above 0.25 A or 1 V
Voltage Outputs:
0 to 120 V at 60 VA, 0 to 240 V at 60 VA. Choice of individually ganged outputs A-B, B-C, C-A, or A-B-C.
Overload Protection:
Input:
Fuse-protected
Power Supply:
Overcurrent, undervoltage/overvoltage, thermal
Amplifiers:
Current-limiting, thermal, fused
Phase Adjustment:
Applicable for each phase to be set from 0 to 360°. Allows operator to set positive-sequence, negative-sequence, and zero-sequence fault conditions.
Test Mode Selection:
Normal, Fault, Post-Fault. Test mode selection has a programmable delay from 0 to 999.9 cycles before initiation test.
Fault Output Adjustment:
Line-to-Neutral:
Single-phase, open delta, T-connect, three-phase wye
Line-to-Line:
Three-phase delta, phase-to-phase
Timer Contacts:
Isolated contacts are selectable for normally open or normally closed. Timer contacts initiate when fault is applied.
Output Frequency:
50/60 Hz or sync to line ±2 Hz
Amplitude Regulation:
Accuracy:
Maximum 1%, typical 0.5%
Harmonic Distortion:
< 1%
Phase Variation:
Accuracy:
±2°
Operating Temperature Range:
32 to 113°F (0 to 45°C)
Storage Temperature:
-20 to +158°F (-20 to 70°C)
Dimensions:
7.25" H x 21.25" W x 13.75" D (184 mm x 540 mm x 349 mm)
With Carrying Case:
16.25" H x 24.5" W x 9.0" D (413 mm x 622 mm x 229 mm)
Weight:
39 lb (86.2 kg)
With Carrying Case:
46 lb (101.2 kg)
For Domestic Customers: Packaging, handling, and order processing included in shipping in all domestic shipments as quoted by the shipping calculator. For International Customers there is a .00 minimum for packaging, handling, and order processing. International shipping to be determined by destination.
Prior to shipment I will need to know the following information (filled out on a form that I will send you) for International Customers or Packages/Freight being Forwarded internationally. International customers may also be subject to a freight forwarder form if applicable.:
(1) Are you the end-user of this item?
(2) If you are not the ultimate end-user of the item, please state the ultimate end user's name.
(3) What is the ultimate country destination?
04/06/20