-40%

Clare HAL (H101) Seaward Clare HAL 101 AC/DC Hipot and DC Insulation Tester

$ 396

Availability: 100 in stock

Description

Clare HAL (H101) Seaward Clare HAL 101 AC/DC Hipot and DC Insulation Tester
Item
Make: Clare
Model: HAL (H101)
Options:
Item Specifics/Condition
Refurbishment
Description
Clare HAL LED hipot tester
AC Flash / Hipot Test
Programmable Voltage Range
0.10 kV-5.00 kV (10V/Step Resolution)
Frequency Independent of Supply
50 or 60 Hz
Voltage Display Range and Accuracy
0.10 kV-5.00kV ±1% ± 5 Counts
Voltage Display Resolution
0.01kV
Current Display Range and Accuracy
0.01mA-20.00mA ±1% ± 5 Counts
Current Display Resolution
0.01mA
Selectable Range of Pass/Fail Levels
0.01mA-20.00mA
Maximum Current Output
20.00mA @5kV
Maximum Current Output Optional Arc Detection
9 Levels
DC Flash / Hipot Test
Programmable Voltage Range
0.10 kV-6.00 kV (10V/Step Resolution)
Programmable Voltage Range Voltage Display Range and Accuracy
0.10 kV-6.00kV ±1% ± 5 Counts
Voltage Display Resolution
0.01kV
Current Display Range and Accuracy
0.01mA-10.00mA ±1% ± 5 Counts
Current Display Resolution
0.01mA
Selectable Range of Pass/Fail Levels
0.01mA-10.00mA
Maximum Current Output
10.00mA
Optional Arc Detection
9 Levels
Insulation Resistance Test
DC Output Voltage
250V, 500, or 1000V Selectable
Display Range
0.01MΩ-500MΩ
Display Range / Accuracy
0.03MΩ - 350 MΩ ± 5% ± 5 Counts
350MΩ -500 MΩ Indication Only
Display Resolution
0.01MΩ
Pass/Fail Level
0.00MΩ-500.0MΩ
Earth / Ground Bond Test
Test Voltage
Nominal 6V AC
Frequency
50 or 60 Hz (independent of supply)
Display Range and Accuracy
0-1500mΩ ±2% ±5 Counts
Display Resolution
1 mΩ
Compliance Test Ranges
Current/Load Resistance/Time
5 A - 1000mΩ - Continuous
10 A - 500mΩ - Continuous
25 A - 200 mΩ - Continuous
30 A - 150 mΩ - 60 secs
40A - 100 mΩ - 60 secs
Settable Output Current Range
0.1A - 40.0A
Selectable Range of Pass/Fail Levels
0-1500 mΩ
Power and Leakage Test
Power Output Rating
Test Voltage
80V - 300V AC 20A nominal (Vin-Vout)
Maximum Power Output
999.9W
Output Power Measurement
Single Phase Power Measurement
Display Range and Accuracy
+/-5% +/- 2 digits (200mV/A).
000.0 to 999.9 VA
Selectable Range of Pass/Fail Levels
000.2 - 1000 VA
Single Phase Power Factor Measurement
Display Range and Accuracy Ratio
0.000 -1.000 ± 0.030
Selectable Range of Pass/Fail Levels
0.000-1.000
Leakage Current Measurement
Display Range and Accuracy
0.10mA-20.00 mA ± 1% ±5 Counts
Display Resolution
0.01mA
Selectable Range of Pass/Fail Levels
0.01mA-20mA
Touch Current Measurement
Display Range and Accuracy
0.02mA - 5.00 mA ± 1% ±5 Counts
Display Resolution
0.01
Selectable Range of Pass/Fail Levels
0.02mA-5.00mA
Measuring Device
IEC/EN 60990 Fig 4
(IEC/EN 60990 Fig 3 or Fig 5 Upon Request)
Images
Term of sale
Included Items:
This sale does not include probes, cables, manuals, power cords or any other accessories unless otherwise stated or pictured.