-40%

Voltech AT3500 Transtest Automatic Transformer Tester/Test Set

$ 5702.39

Availability: 100 in stock

Description

Voltech AT3500 Transtest Automatic Transformer Tester/Test Set
Comes with a manual and what you see in the pictures. If you don't see it, you probably won't get it.
Specifications are from Voltech and may vary slightly due to upgrades, options, or revisions this unit may or may not have.
This unit will ship fully tested and guaranteed to work for 30-days, parts and labor, excluding freight.
The Unit's Serial Number Tag Reads:
Serial Number:
TA08/9244
Date of Manufacture:
11-30-95
Power Requirements:
110/220 V ±20%, 45-65 Hz~.
The Measurement Verification Fixture's Information Reads:
Part Number:
01-028-0-5A / 01-028-0-3A
D.C. Resistance Specifications:
Range:
500 µΩ to 100 kΩ
Accuracy:
±1% of reading ±0.1 mΩ
Inductance Specifications:
Range:
500 nH to 10,000 H
Accuracy (At zero bias and recommended test frequency. Accuracy valid for values of Q > 1):
±1% of reading ±100 nH ±0.1% per kHz
Test Frequency:
20 Hz to 300 kHz
DC Bias Current:
0 to 1 A
Output Voltage:
10 mV - 10 Vrms
Accuracy for Q:
Typically ±10% at a Q of 30 at 1 kHz
Turns Ratio Specifications:
Ratio:
0.0001 to 10,000
Accuracy (For ratios from 0.001 to 1000: voltage > 10 mV; winding impedance < 100 Ω):
±1% of reaing ±0.05% per kHz
Typical Repeatability:
0.3%
Test Frequency:
20 Hz to 100 kHz
Output Voltage:
10 mV - 10 Vrms
Magnetizing Current Specifications:
Range:
100 µA to 2 Arms (4 A pk)
Accuracy:
10 mA to 2 A:
±1.5% of reading ±0.5 mA
100 µA to 10 mA:
±1.5% of reading ±5 µA
Test Frequency:
20 Hz to 2500 Hz
Output Voltage:
10 V to 500 Vrms
Peak Drive Current:
4 A peak @ 10 - 125 V, 2 A peak @ 125 - 250 V, 1 A peak @ 250 - 500 V
Open-Circuit Voltage Specifications:
Range:
0 - 500 Vrms ac or 0 - 800 V dc
Accuracy:
±1% of reading ±10 mV
Test Frequency:
20 Hz to 2500 Hz
Output Voltage:
10 V to 500 Vrms
Hi-Pot (EHT) Specifications:
Range:
500 V to 5 kV ac
Test Frequency:
50 Hz to 60 Hz
Trip Current Level:
1 - 15 mA peak depending on test voltage
Accuracy (Test Voltage):
±3%
Accuracy (Trip Current):
±0.5 mA
Ramp Up Time:
0.1 to 60 seconds
Dwell Time:
0.1 to 60 seconds
Ramp Down Time:
0.1 to 60 seconds
Interwinding Capacitance Specifications:
Range:
5 pF to 1 µF
Accuracy (At recommended test voltage and frequency):
±1% of reading ±3 pF ±0.1% per kHz
Test Frequency:
20 Hz to 300 kHz
Output Voltage:
10 mV - 10 Vrms
Inter-Turns Stress Specifications:
Range:
10 mV to 50 W
Accuracy (Sinewave):
±2% of reading ±(500 µA x test voltage) ±0.1% per kHz
Test Frequency:
Sinewave:
20 Hz to 2500 Hz
Squarewave:
20 Hz to 500 kHz (at frequencies above 30 kHz the square wave is a pulse waveform)
Output Voltage:
Sinewave:
10 V to 500 Vrms
Squarewave:
±10 V to ±800 V peak
Dwell Time:
0.1 to 60 seconds
Leakage Inductance Specifications:
Range:
500 nH to 10 H
Accuracy (At recommended test voltage and frequency. Accuracies valid where Leakage inductance < 10% of the Inductance value of the energized winding.):
±3% of reading ±l100 nH ±0.1% per kHz
Test Frequency:
20 Hz to 300 kHz
Output Voltage:
10 mV to 1 Vrms
Maximum Drive Current:
1 A
Leakage Current Specifications:
Range:
1 µA to 1000 µA
Accuracy:
±2% of reading ±5 µA
Test Frequency:
20 Hz to 2500 Hz
Output Voltage:
10 V to 500 Vrms
Insulation Resistance Specifications:
Range:
1 MΩ to 10,000 MΩ
Accuracy:
±5 MΩ at 100 MΩ
Output Voltage:
50 V dc to 850 V dc
Dwell Time:
0.1 to 60 seconds
Environment Specifications:
Operating Temperature:
0°C to 40°C
Temperature Accuracy:
23°C ±5°C
Storage Temperature:
-40°C to +70°C
Humidity:
10% to 90% RH (non condensing)
Dielectric Strength Specifications:
AC Line Input to Case:
2 kV ac 50/60 Hz for 1 minute
Safety Interlock Specifications:
Type:
Schmerzal AZ16ZV
Approvals:
UL, CSA< VDE.
Power Requirement Specifications:
Line Input Voltage:
80 Vrms to 265 Vrms
Line Input Frequency:
50/60 Hz
Protection:
Fuse 20 mm 8A (T)
Power Consumption:
150 W, 250 VA max.
Mechanical Specifications:
Weight:
27 kg
Dimensions:
484 mm W x 310 mm H x 545 mm D
0.00 minimum for packaging, handling, and order processing. Shipping to be determined by destination.
Prior to shipment I will need to know the following information (filled out on a form that I will send you) for International Customers or Packages/Freight being Forwarded internationally. International customers may also be subject to a freight forwarder form if applicable.:
(1) Are you the end-user of this item?
(2) If you are not the ultimate end-user of the item, please state the ultimate end user's name.
(3) What is the ultimate country destination?
12/22/17